In the process of use, the packing of the gate valve will leak, which may be caused by the wear and aging of the packing, or the unstable operation of the pipeline system or improper operation of the gate valve. In order not to affect the normal operation of the pipeline system, but also to solve the problem of leakage of the gate valve packing, the requirements of the gate valve packing can be replaced in the normal operation of the pipeline, this article is about the replacement of the gate valve packing method in this case.

   Gate valve is the most common type of industrial valve, widely used in petroleum, petrochemical, power station, long-distance pipeline and shipbuilding and other industrial fields. In the process of use, the packing of the gate valve will leak, which may be caused by the wear and aging of the packing, or the unstable operation of the pipeline system or improper operation of the gate valve. Whatever the reason, once the leakage, will affect the normal operation of the pipeline system, but also further accelerate the wear and tear of the valve, shorten the life of the valve, and even cause pollution to the environment, to the equipment to bring about safety hazards. In order not to affect the normal operation of the pipeline system, but also to solve the problem of leakage of the gate valve packing, the requirements of the gate valve packing can be replaced in the normal operation of the pipeline, this article is about the replacement of the gate valve packing method in this case.

 一、 Preparations

    1、Material preparation:Prepare packing material that matches the size of bonnet packing box, appropriate amount of leakage detection fluid and cotton yarn.

                                                           

     2、Tools preparation:Prepare two spanners, one pair of scissors, two screw spinners (100mm), one brush (25mm) in line with the packing gland nut size.

    二、 Operational steps

    1、Use a spanner to loosen the packing gland nut slowly and evenly, and observe the pressure leakage in the packing box.

    2、To determine the pressure leakage is stable, no longer increase, remove the packing gland nut, lift the packing gland, to observe the leakage and packing box original packing upward movement.

    3、When the pressure leakage in the packing box is stable and decreasing, and the packing is slightly shifted upward basically stable, then we can continue to enter the following steps.

     4、Cut the prepared packing into length and packing box circumference in line with the two end face for 45 ° inclined interface short section.

     5、Take a section of cut packing, around the valve stem circle, flat pressure into the packing box, not filled, continue to add the second, pay attention to the two interfaces should be staggered position of about 120 °, until filled.

    6、Cover the packing gland, screw on the packing gland nut, use a spanner to tighten the nut symmetrically and evenly, and press the packing gland moderately.

   7、Check whether the packing is leaking with the leakage detection tool, if there is leakage, tighten the gland nut properly to further tighten the packing, until there is no leakage.

    8、Tidy up the tools and clean up the site.

    9、Do a good job of adding packing records.

                                              

    三、 Technical requirements and considerations

    1、 Plus packing should be sure that the gate valve is in the fully closed position, the operation of the human body is strictly prohibited against the valve stem (with the upper sealing structure of the valve, the valve can be opened to the fully open position).

   2、Loosen the packing gland nut should be slow, even force, pay close attention to the observation of pressure leakage, if loosening the nut found that the leakage is too large, you should immediately tighten the packing gland nut, stop the packing operation.

     3、Each section of packing end tilt interface for 30 ° ~ 45 °, the length should be just around the stem of a circle, pressed into the packing box, the two ends of the tilt interface should be flat butt, the upper and lower two packing interface should be staggered about 90 ° ~ 120 °.

   4、Tighten the packing gland nut, should be symmetrical, uniform force, the degree of compression of the gland should meet the packing without leakage, the valve stem up and down movement is flexible.

     5、The packing cannot be added too full, in order to tighten the packing box depth of no more than 3/4 is appropriate.

     6、After the operation is completed, the tool should be cleaned and maintained.

 